Power And Harmonic Analyzer

Distributor / Channel Partner of a wide range of products which include hioki pw8001 three phase power analyzer, fluke 1770 series three-phase power quality analyzers, fluke-434-ii power quality and energy analyzers, fluke- 435-ii, advanced pq and energy analyzer and chauvin arnoux power and energy quality analyzer ca8336.

Hioki PW8001 Three Phase Power Analyzer

  • Foil Print

₹ 7 Lakh /Piece Get Latest Price

Product Brochure
Usage/ApplicationIndustrial Use
Model Name/NumberHioki PW8001
ParametersDC, 0.1 Hz to 5 MHz, 3-phase 4-wire, High Precision Power Analyzer for Motor and Inverter Efficiency
Display TypeDigital
Accuracy50/60 Hz: 0.02% of reading + 0.05% of range
Power Consumption100 V to 240 V AC, 50/60 Hz, 230 VA
DimensionApprox. 430 mm (16.93 in) W x 221 mm (8.70 in) H x 361mm (14.21 in) D
FrequencyU7001: DC, 0.1 Hz to 1 MHz U7005: DC, 0.1 Hz to 5 MHz

Minimum order quantity: 1 Piece

The PW8001 sets a new benchmark for complete power analysis solutions with Hioki being the only manufacturer that offers industry-leading power analyzers and a wide portfolio of high-accuracy current sensors both developed and manufactured by Hioki. This enables to align their performance and results in more accurate and stable measurements from DC to high frequencies and low power factor measurements thanks to functions like the automatic phase shift correction.

Fluke 1770 Series Three-Phase Power Quality Analyzers

₹ 8.27 Lakh /Piece Get Latest Price

Number of inputs4 inputs, 3 phases and neutral referenced to PE (5 connectors)
Resolution24-bit synchronous sampling
Scaling1:1, variable for use of potential transformers
Resolution14-bit synchronous sampling
Data storageFluke 1773/1775: 8 GB internal (expandable with microSD card)
Memory sizeTypical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events.

Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord

With the 1770 Series you’ll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.

Fluke 1770 Series Three-Phase Power Quality Analyzers

₹ 10.03 Lakh /Piece Get Latest Price

Maximum input voltage1000 V rms / 1000 V dc (1700 Vpk)
Sampling frequency80 kS/s at 50/60 Hz
Resolution14-bit synchronous sampling
Number of inputs2
Number of inputs4 inputs, 3 phases and neutral referenced to PE (5 connectors)
Measurement category1000 V CAT III / 600 V CAT IV

Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord

With the 1770 Series you’ll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.

Fluke 1770 Series Three-Phase Power Quality Analyzers

₹ 11.74 Lakh /Piece Get Latest Price

Power ConsumptionIEEE 1459
Resolution24-bit synchronous sampling
Measurement range+-8 kV
Resolution14-bit synchronous sampling
WarrantyAnalyzer: 2 years (battery not included)
Number of inputs4 inputs, 3 phases and neutral referenced to PE (5 connectors)
Sampling frequency80 kS/s at 50/60 Hz

Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord

With the 1770 Series you’ll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.

Fluke-434-II Power Quality And Energy Analyzers

₹ 5 Lakh /Piece Get Latest Price

Product Brochure
Model Name/NumberFluke 434-II

Analyze power quality issues, calculate the costs of wasted energy and prevent downtime with the Fluke 434-II Energy Analyzer and Fluke 435-II Power Quality and Energy Analyzer.

  • Advanced power quality health—At-a-glance power quality health data in real time so you can make better maintenance decisions
  • Energy loss calculator—Discover the costs of energy loss specifically caused by poor power quality
  • Highest safety rating in industry—CAT III 1000 V / CAT IV 600 V

Fluke- 435-II, Advanced PQ And Energy Analyzer

₹ 6.50 Lakh /Piece Get Latest Price

Product Brochure
Model Name/NumberFLUKE-435-II

The new 430 Series II Power Quality and Energy Analyzers offer the best in power quality analysis and introduce, for the first time ever, the ability to monetarily quantify energy losses.  The new Fluke 434, 435 and 437 Series II models help locate,predict, prevent, and troubleshoot power quality problems in threephase and single-phase power distribution systems. Additionally,the Fluke-patented energy loss algorithm, Unified Measurement, measures and quantifies energy losses dueto harmonics and unbalance issues, allowing the user to pinpoint the origin of energy waste within a system.

Chauvin Arnoux Power And Energy Quality Analyzer CA8336

₹ 4 Lakh /Piece Get Latest Price

Product Brochure
Model Name/NumberC A 8336

Designed for test and maintenance teams working in industrial or administrative buildings, the Qualistar+ C.A 8336 can be used to obtain a snapshot of the main features characterizing the quality of the electrical network.. This analyser's functions make it the ideal instrument for preventive or corrective maintenance. It can also be used to perform a complete energy survey of an installation.
For sizing installations or troubleshooting switching faults, the C.A 8336 is equipped with Inrush and TrueInrush functions.
Easy to handle and particularly compact, this instrument also offers a large number of calculated values and several processing functions. The C.A 8336 is equipped with 4 voltage measurement channels and 4 current measurement channels. The C.A 8336 captures and records all the parameters, transients, alarms and waveforms simultaneously.

When current sensors are connected to the C.A 8336, it recognizes them automatically. It also offers the possibility of mixing different types of current sensors and configuration of the ratios allows direct reading of the measurements.

Specially designed for work in the field:

  • Direct access to the main functions (configuration, etc.)
  • Direct access to the measurements (harmonics, flicker, etc.)
  • Voltage/current inputs equipped with colour-coded inserts
  • Large colour TFT screen for easy reading
  • Battery life: 13 hrs

The multiple functions of the Qualistar+ C.A 8336 make it a versatile instrument. It is suitable for applications up to 1,000 V in CAT III and 600 V in CAT IV.